CBYFF - MT TONER 101, EP1081

  • MSDS: CBYFF
  • Manufacturer: MINOLTA CORP
  • Product Name: MT TONER 101, EP1081
  • National Stock Number: 6850-00N072432
Product Identification

Product ID:MT TONER 101, EP1081
MSDS Date:10/17/1994
FSC:6850
NIIN:00N072432
MSDS Number: CBYFF

Responsible Party
MINOLTA CORP
101 WILLIAMS DR
RAMSEY, NJ 07446
US

Emergency Phone: 201-825-4000

Info Phone: 201-825-4000

Cage: GO339

Contractor
MINOLTA CORPORATION
RAMSEY, NJ 07446 US

Telephone: 201-825-4000

Cage: 23736

Ingredients

STYRENE ACRYLATE COPOLYMER

CAS: 25153-46-2

Fraction By Weight: >80%

OSHA PEL N/K

ACGIH TLV: N/K


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 5-10%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


ORGANIC PIGMENT

CAS: 32517-36-5

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K


PROPENE POLYMERS; (POLYPROPYLENE)

CAS: 9003-07-4

RTECS: UD1842000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K


SILICA, AMORPHOUS FUMED; (AMORPHOUS SILICA)

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: <1%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3

Hazards

LD50 LC50 Mixture:LD50: (ORAL, RAT) >5.0 G/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MINIMAL RESP TRACT IRRIT MAY
OCCUR AS W/EXPOS TO LG AMTS OF ANY NONTOX DUST. MAY CAUSE COUGH &
RAISE PHLEGM. CHRONIC: NONE. TONER PRESENT A LOW HAZ FOR USUAL
OCCUP SETTINGS. BASED ON AVAIL DATA , HUMAN EXPOS TO TONER HAS BEEN
SHOWN TO CAUSE MINIMAL RESP TRACT IRRIT AS MAY OCCUR W/LG AMTS OF
ANY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON BLACK: IARC MONOGRAPHS ON THE
EVALUATION OF CARCINOGENIC RISK OF CHEMICALS TO MAN, VOL 65,
1996:GROUP 2B.
Effects of Overexposure:HLTH HAZ: NON-TOX DUSTS. RSLTS OF ONE ANIMAL
STUDY WHERE RATS INHALED TONER THAT WAS 10 TIMES MORE RESPIRABLE
THAN COMMERCIALLY AVAIL TONER WERE OBSERVED TO HAVE NO LUNG CHANGES
AT LOW EXPOS (MOST REL EVANT LEVEL TO POTNTL HUMAN EXPOS). AT HIGH
LEVELS A SLIGHT DEGREE OF LUNG FIBROSIS WAS OBSERVED DUE TO EXCESS
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE LISTED BY MANUFACTURER.

First Aid

First Aid:INHALATION: WASH NOSTRILS, RINSE MOUTH. INGESTION: DILUTE
STOMACH CONTENTS WITH SEVERAL GLASSES OF WATER. EYES: FLUSH WITH
WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND WATER.

Fire Fighting

Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:IF DISPERSED IN AIR, TONER, LIKE MOST
FINELY DIVIDED ORGANIC POWDERS, MAY FORM AN EXPLOSIVE MIXTURE.

Accidental Release

Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN MINOLTA
EQUIPMENT. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE.
Supplemental Safety and Health
EFTS OF OVEREXP: AMTS OF DUST RETAINED IN THE LUNGS FOR A PRLNGD
INTERVAL.

Chemical Properties

Spec Gravity:1.15 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK POWDER; FAINT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION ARE TOXIC.
AVOID BREATHING OF SMOKE.

Disposal

Waste Disposal Methods:WASTE MAY BE DISPOSED OR INCINERATED UNDER
CONDITIONS WHICH MEET ALL FEDERAL, STATE AND LOCAL ENVIRONMENTAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.